Manual Rebuild using ARCCONF (Command Line Utility)

Use the ARCCONF command 'setstate' in order to assign the newly added drive to be a hot spare. Enter the number of the logical device that is in degraded state and needs to be rebuilt. In this example, the new drive on Channel 0 ID 0 is to be added as a hot spare for Logical Drive 1.

ARCCONF SETSTATE 1 DEVICE 0 0 HSP LOGICALDRIVE 1

For further information on ARCCONF, please refer to the Command Line Interface User's Guide


출처 - http://ask.adaptec.com/app/answers/detail/a_id/17082/~/how-to-rebuild-a-degraded-raid-array-on-a-sata-or-sas-raid-controller%3F